{"product_id":"ledsion-5w-explosion-proof-emergency-exit-sign-class-i-division-1","title":"5W Explosion-Proof Edge-Lit Exit Sign – Class I Division 1 | LSEX-5WVNRD180","description":"\u003cp\u003eThe \u003cstrong\u003eLEDSION 5W Explosion-Proof Emergency Edge-Lit Exit Sign Light\u003c\/strong\u003e is C1D2 designed for \u003cstrong\u003ehazardous locations\u003c\/strong\u003e where flammable gases, vapors, or combustible dust may be present. Built to meet strict \u003cstrong\u003eUL hazardous location standards\u003c\/strong\u003e, this fixture provides reliable \u003cstrong\u003ered EXIT indication\u003c\/strong\u003e and long-duration emergency illumination to ensure safe evacuation during power outages.\u003c\/p\u003e\n\u003cp\u003eWith a \u003cstrong\u003esealed, IP66-rated enclosure\u003c\/strong\u003e, lightweight construction, and \u003cstrong\u003eintegrated junction box with emergency driver\u003c\/strong\u003e, this exit sign delivers dependable performance in harsh indoor and outdoor environments. When normal power is restored, the unit automatically switches back to mains power operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for \u003cstrong\u003ewet locations\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLightweight and compact design\u003c\/strong\u003e for easy installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated junction box\u003c\/strong\u003e with driver and emergency backup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIP66 ingress protection\u003c\/strong\u003e – dust-tight and water-resistant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLow energy consumption\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3-hour (180-minute) emergency operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStainless-steel exposed fasteners\u003c\/strong\u003e for high corrosion resistance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlternate EXIT legends and multiple language options available\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSealed unit design\u003c\/strong\u003e – battery is not replaceable\u003cbr\u003e\u003cem\u003e(Entire exit sign must be replaced when battery reaches end of life)\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically reactivates via \u003cstrong\u003emains power\u003c\/strong\u003e when power is restored\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for \u003cstrong\u003eUL 844 hazardous location environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eHazardous Location Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClass I, Division 1\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClass I, Division 2, Groups A, B, C, D\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClass II, Division 1, Groups E, F, G\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClass II, Division 2, Groups F, G  \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eClass III\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e LEDSION Lighting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e EX-5WVNRD180 \/ LS-ES-A01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRated Power:\u003c\/strong\u003e 5W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEmergency Duration:\u003c\/strong\u003e 3 hours (180 minutes)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e AC 100–277V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLight Color:\u003c\/strong\u003e Red\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExit Display:\u003c\/strong\u003e EXIT with dual arrow indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eViewing Sides:\u003c\/strong\u003e Double-sided EXIT logo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFixture Size:\u003c\/strong\u003e 417 × 425 × 116 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e –20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHousing Material:\u003c\/strong\u003e ABS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLighting Type:\u003c\/strong\u003e Edge-lit LED exit sign\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUL 924\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUL 844\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUL1598 \/ UL1598A\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUL913\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and petrochemical plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBattery rooms and pump stations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGrain handling and dust-hazard areas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMarine and offshore platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial corridors, stairwells, and emergency exits in hazardous locations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eSelection and related resources\u003c\/h2\u003e\n\u003cp\u003eConfirm the complete Class, Division, group, temperature-code, ambient, voltage, mounting, and certification requirements for the installation before ordering. See the \u003ca href=\"\/en-ca\/blogs\/guides\/hazardous-location-lighting-where-explosion-proof-fixtures-are-required\"\u003eExplosion-Proof Lighting Buyer’s Guide\u003c\/a\u003e or compare all products in the \u003ca href=\"\/en-ca\/collections\/explosion-proof-lighting\"\u003eExplosion Proof Lighting collection\u003c\/a\u003e.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eRelated technical guide:\u003c\/strong\u003e Compare the classifications in \u003ca href=\"\/en-ca\/blogs\/guides\/class-i-division-1-vs-division-2-lighting\"\u003eClass I Division 1 vs. Division 2 Lighting\u003c\/a\u003e.\u003c\/p\u003e","brand":"Exit Sign Shop","offers":[{"title":"LSEX-5WVNRD180","offer_id":43677158277186,"sku":"LSEX-5WVNRD180","price":1273.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0671\/2442\/8866\/files\/Explosionproofedgelitexitsignlight-2_43693288-f828-4d73-9833-082c8d7da13b.webp?v=1777171528","url":"https:\/\/exitsignshop.com\/en-ca\/products\/ledsion-5w-explosion-proof-emergency-exit-sign-class-i-division-1","provider":"Exit Sign Shop","version":"1.0","type":"link"}